  universal ac input / full rangebuilt-in active pfc function, pf>0.95 high efficiency up to 89% protections: short circuit / overload / over voltage / over temperature dc ok signal 5 years warranty withstand 300vac surge input for 5 secondsbuilt-in constant current limiting circuit 1u low profile 41mm built-in cooling fan on-off control built-in built-in remote sense function specification hrp-300-3.3 HRP-300-5 hrp-300-7.5 hrp-300-12 hrp-300-15 hrp-300-24 hrp-300-36 hrp-300-48 model dc voltage rated current current range rated power ripple & noise (max.) note.2 output voltage adj. range voltage tolerance note.3 line regulation load regulation setup, rise time hold up time (typ.) voltage range note.5 frequency range power factor (typ.) efficiency (typ.) input environment inrush current (typ.) leakage current over temperature safety standards harmonic current emi conduction & radiation safety & ems immunity emc (note 4) withstand voltage isolation resistance working temp. working humidity storage temp., humidity temp. coefficient vibration mtbf dimension others note packing overload over voltage protection ac current (typ.) 3.3v 5v 7.5v 12v 15v 24v 36v 48v 60a 60a 40a 27a 22a 14a 9a 7a 0 ~ 60a 0 ~ 60a 0 ~ 40a 0 ~ 27a 0 ~ 22a 0 ~ 14a 0 ~ 9a 0 ~ 7a 198w 300w 300w 324w 330w 336w 324w 336w 80mvp-p 90mvp-p 100mvp-p 120mvp-p 150mvp-p 150mvp-p 250mv p-p 250mvp-p 2.8 ~ 3.8v 4.3 ~ 5.8v 6.8 ~ 9v 10.2 ~ 13.8v 13.5 ~ 18v 21.6 ~ 28.8v 28.8 ~ 39.6v 40.8 ~ 55 .2v 2.5% 2.0% 2.0% 1.0% 1.0% 1.0% 1.0% 1.0% 0.5% 0.5% 0.5% 0.3% 0.3% 0.2% 0.2% 0.2% 1.0% 1.0% 1.0% 0.5% 0.5% 0.5% 0.5% 0.5% 1000ms, 50ms/230vac 2500ms, 50ms/115vac at full load 16ms/230vac 16ms/115vac at full load 85 ~ 264vac 120 ~ 370vdc 47 ~ 63hz pf>0.95/230vac pf>0.99/115vac at full load 6 ~ 7v 9.4 ~ 10.9v 14.4 ~ 16.8v 18.8 ~ 21.8v 30 ~ 34.8v 41.4 ~ 48.6v 57.6 ~ 67.2v 5a/115vac 2.5a/230vac 35a/115vac 70a/230vac <1.2ma / 240vac 105 ~ 135% rated output power 3.96 ~ 4.62v protection type : constant current limiting, recovers automatica lly after fault condition is removed protection type : shut down o/p voltage, re-power on to recover protection type : shut down o/p voltage, recovers automatically after t emperature goes down ul60950-1, tuv en60950-1 approved compliance to en55022 (cispr22) class b compliance to en61000-3-2,-3 compliance to en61000-4-2,3,4,5,6,8,11, env50204, en55024, en 61000-6-2, heavy industry level, criteria a i/p-o/p:3kvac i/p-fg:1.5kvac o/p-fg:0.5kvac i/p-o/p, i/p-fg, o/p-fg:100m ohms / 500vdc / 25 / 70% rh -40 ~ +70 (refer to output load derating curve) 20 ~ 90% rh non-condensing -40 ~ +85 , 10 ~ 95% rh 0.03%/ (0 ~ 50 ) 10 ~ 500hz, 5g 10min./1cycle, 60min. each along x, y, z axes 176k hrs min. mil-hdbk-217f (25 ) 199*105*41mm (l*w*h) file name:hrp-300-spec 2010-11-29 features : 1. all parameters not specially mentioned are measured at 230vac input, r ated load and 25 of ambient temperature. 2. ripple & noise are measured at 20mhz of bandwidth by using a 12" twisted pair- wire terminated with a 0.1uf & 47uf parallel capacitor. 3. tolerance : includes set up tolerance, line regulation and load regula tion. 4. the power supply is considered a component which will be installed into a fi nal equipment. the final equipment must be re-confirmed that it still me ets emc directives. 5. derating may be needed under low input voltages. please check the derati ng curve for more details. for guidance on how to perform these emc tests, please refer to ?emi testing of c omponent power supplies.? (as available on http://www.meanwell.com) h r p - 3 0 0 s e r i e s 300w single output with pfc function 0.95kg;15pcs/15.3kg/0.69cuft 80% 82% 86% 88% 88% 87% 88% 89% dc ok signal psu turns on : 3.3 ~ 5.6v ; psu turns off : 0 ~ 1v function 100 5 for 3.3v,5v,7.5v ; 95 5 for others (tsw2: power diod detect on heatsink of e) 90 5 (tsw1: detect on heatsink of power transistor) fan control (typ.) load 35 15% or rth2 50 fan on
ambient temperature ( ) load (%) -40 0 10 20 30 40 50 60 70 (horizontal) mechanical specification case no.980a unit:mm 300w single output with pfc function file name:hrp-300-spec 2010-11-29 derating curve output derating vs input voltage input voltage (v) 60hz ta = 25 85 100 125 135 155 264 100 90 80 70 60 50 40 load(%) block diagram fosc : 70khz o.l.p. o.t.p. emi inrush active filter current limiting rectifiers & pfc i/p fg pwm pfc circuit detection power switching filter & rectifiers +v +s control control o.v.p. -v -s dc ok h r p - 3 0 0 s e r i e s 20 40 50 60 80 100 terminal pin no. assignment pin no. pin no. 12 4,5 3 6,7 assignment assignment dc output -v dc output +v fg ac/l ac/n hrs df11-08dp-2ds or equivalent connector pin no. (cn100) : assignment pin no. 78 5 3 1,2,4,6 assignment nc mating housing hrs df11-8ds or equivalent terminal hrs df11-**sc or equivalent +s -s dc-ok gnd 41 18 12.5 1 2 7 8 cn100 18 12.5 11 9.2 127.4 105 75 15 air flow direction 17max. 167.5 168.5 199 4-m4 l=5 fan 120 led svr 12.25 168.5 12.25 12.25 4-m4 l=6 12.25 167.5 4-m4 l=6 42.5 12 3 4 5 6 7


▲Up To Search▲   

 
Price & Availability of HRP-300-5

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X